High-Accuracy Digital Contact Sensor
GT2 series
Extension Board for GT2-100PGT2-E3P
Specifications
Model |
GT2-E3P |
|||
Mounting method |
Installed into GT2-100N/100P (up to 3 boards) |
|||
Output |
PNP output |
|||
Main unit/expansion unit |
- |
|||
Power supply voltage |
Supplied from GT2-100N/100P |
|||
Power consumption |
Normal |
4,200 mW max. (30 V, 140 mA max.)*1 |
||
Power saving (Eco) |
4,000 mW max. (30 V, 133.3 mA max.) |
|||
Display power |
Measured value display |
- |
||
Other displays |
||||
Display range |
||||
Display resolution |
||||
Sampling rate |
1,000 times/sec. |
|||
Control input |
Timing/preset/ |
No-voltage input |
||
Control output |
HH/HI/GO/LO/LL |
PNP open collector, 30 V 50 mA or less*2, residual voltage 1 V or less |
||
Response time |
hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C14 to 122 °F(No freezing) |
||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET |
|||
Power supply/I/O cable |
I/O: 30-pin connector (MIL standard) |
|||
Weight |
Approx. 80 g |
|||
*1For GT2-100 Series, when the maximum number of sensor heads are connected and all units are set to power saving mode. |