CMOS Multi-Function Analog Laser Sensor

IL series

CatalogsView Catalog

Sensor headsIL-600

Specifications

Model

IL-600

Reference distance

600 mm23.62"

Measurement range

200 to 1000 mm7.87" to 39.37"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. ø1.6 mmø0.06"

Linearity

±0.25% of F.S. (200 to 600 mm7.84" to 23.62")*2*3
±0.5% of F.S. (200 to 1000 mm7.84" to 39.37")*2*3

Repeatability

50 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.08% of F.S./°C*5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 5,000 lux*6

Ambient temperature

-10 to +50 °C14 to 122 °F(No condensation or freezing)

相对湿度

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 135 g

*1The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50.
*2Value when measuring the KEYENCE standard target (white diffuse object).
*3F。S. of each model is as follows. IL-030: ±5 mm±0.20"IL-065: ±10 mm±0.39"IL-100: ±20 mm±0.79"IL-300: ±140 mm±5.51"IL-600: ±400 mm±15.75"IL-2000: +1000 to -1500 mm39.37" to -59.05"
*4Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*5F。S. of each model is as follows. IL-030: ±5 mm±0.20"IL-065: ±10 mm±0.39"IL-100: ±20 mm±0.79"IL-300: ±140 mm±5.51"IL-600: ±400 mm±15.75"
*6Value when the sampling rate is set to 2 ms or 5 ms.

Other Models