放大器单元电缆型扩展单元PNPFS-N42P

Specifications

Model

FS-N42P

Type

电缆

Output

PNP

Main unit/expansion unit

扩展单位

Response time

23 µs (S-HSPD*1/50μs(HSPD*2)/250μs(细)/500μs(Turbo)/ 1 ms(超级)/ 4 ms(超)/ 16 ms(Mega)/ 64 ms(Tera)

Number of control outputs

1

Number of external inputs

Light source LED

Transmitter side: Red, four-element LED (wavelength: 660 nm)

Control output

Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)
Residual voltage: 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)

External input

Input time: 2 ms (ON) /20 ms (OFF) or longer*3

单位扩展

Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.

保护电路

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

相互干扰预防

S-HSPD / HSPD:0单位,精细:4个单位,涡轮增压/超级/超/ Mega / TERA:8个单位(相互干扰预防值是在齐全时显示的两倍。)

Power supply

电源电压

10至30 VDC(包括10%纹波(P-P)或更低),2类或LPS*4

Power consumption

During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
生态:840 mW或更少(33马或更少at 24 V/60 mA or less at 12 V)
ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*5

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less

Ambient temperature

-20 °C-4 °F到+55°C+131°F.(no freezing)*6

Vibration resistance

10到55 Hz;双幅度1.5毫米0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500米/秒2; 3 times each for X, Y, and Z axes

Case material

主机和盖子:聚碳酸酯

Weight

Approx. 48 g

*1Restrictions when S-HSPD is selected
对于检测模式,无法选择区域检测,区域%模式,数据,上升沿和下降沿。
Output timer, Limit Detection, and Display Gain cannot be used.
FULL cannot be selected for the ECO function.
*2Restrictions when HSPD is selected
Display Gain cannot be used.
*3The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
*4When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
*5The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.
*6When expanded by 1 to 2 units: -20°C-4°Fto +55°C+131°F. When expanded by 3 to 10 units: -20°C-4°Fto +50°C+122°F.
When expanded by 11 to 16 units: -20°C-4°Fto +45°C+ 113°F. When using 2 outputs, 1 unit is counted as 2 units.
The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.
Exercise special care when installing the product in an airtight space.