Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type)LR-XN11C

Specifications

Model

LR-XN11C

Type

NPN Output/PNP Output (Selectable output)

Cable/Connector

M8 connector*1

Main Unit/Expansion Unit

Main Unit (expansion not possible)

No. of Control Outputs

2*2

No. of External Inputs

1*2

Response Time

500 µs*3/ 1 ms / 3 ms / 10 ms / 200 ms可选择

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs
Residual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA), PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

Power supply

电源电压

16 to 30 VDC*4(including 10% ripple (P-P) or less), class 2

Power consumption

在正常操作期间:1150 MW(47 mA或24 V,16 v,64mA或更低,6 v),ECO ON /全部:985 MW(在24 V,53mA或16 v,53mA或更低,16 v)(不包括负载电流)

Environmental resistance

Ambient temperature

−20 to +55°C-4°F至131°F(no freezing)*5

相对湿度

35至85%RH(无凝结)

抗振

10 to 500 Hz; Power Spectral Density: 0.816 G2/赫兹;x,y和z方向

Shock resistance

500米/秒2(50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

配件

Instruction manual

Weight

Approx. 22 g

*1Ensure the cable length is 30 m98.4'or less for the M8 connector type. Ensure the cable length is 20 m65.6'or less when connecting via IO-Link.
*2Output 2 and the external input are selectable.
*3If 500 µs is selected, the following limitations apply.
·只能执行2点校准。
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*4When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5Expansion by 1 or 2 units: −20 to +55°C-4°F至131°F; Expansion by 3 to 10 units: -20 to +50°C-4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C-4°F to 113°F