Self-contained CMOS Laser Sensor
LR-Z系列
Rectangular w/ cable type, 500 mmLR-ZH500N
Specifications
Model |
LR-ZH500N |
|||
Type |
U.C.D. Function |
|||
Appearance |
Rectangular |
|||
Output |
NPN |
|||
Cable connection |
2 m cable |
|||
Detectable distance |
35 to 500 mm1.38" to 19.69"(465 to 0)*1 |
|||
标准可检测偏差 |
35 to 180 mm1.38" to 7.09":9毫米0.35“ |
|||
Display resolution |
1 to 5 (1 to 5 mm0.04" to 0.20") |
|||
Spot size |
Approx. ø3 mmø0.12" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
光源 |
Type |
红色激光(660nm) |
||
Laser class |
Class 2 laser product (IEC60825-1) |
|||
功能 |
Indicator |
3-digit 7-segment display (white), |
||
计时器 |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
电源电压 |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
NPN Open collector, |
|||
保护电路 |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*2, Diversey*2 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 10,000 lux or less |
|||
Ambient temperature |
-10到+ 50°C14 to 122 °F(No freezing) |
|||
Storage temperature |
-25 to +75 °C-13 to 167 °F(No freezing) |
|||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
耐压 |
1,000 Vac,50/60 Hz,1分钟 |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
案例:SUS316L,显示:PE,镜头盖:PMMA具有耐刮擦涂层, |
|||
Accompanying items |
Instruction Manual, |
|||
Weight |
Approx. 110 g (Including cable) |
|||
*1Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. |